Media:
Accuracy in Point Velocity:
Repeatability:
Response Time:
Gas Pressure:
Gas Temperature:
Supply Voltage:
Output:
Load Resistance:
Operating Temperature Range:
Wetted Parts:
Probe Dimensions:
Housing:
Electrical Connection:
Mounting:
Weight: |
|
Air, nitrogen, or non-corrosive, non-combustible gases
±2% FS over 32 to 122°F (0 to 50°C) and 5 to 30 psia (0.35 to 2 kg/cm2)
±0.2% full scale
0.2 seconds to 63% of final velocity value
100 psig (7 kg/cm2 G) maximum
0 to 150°F (-18 to 66°C)
24 VAC, 0.5 A
4-20 mA nonlinear; proportional to gas mass velocity
50 ohms minimum, 500 ohms maximum
32 to 122°F (0 to 50°)
304 SS probe, glass coated sensor, epoxy
¼" (6.35 mm) O.D., 13 (33 cm) length
Dustproof NEMA 2 anodized aluminum
¾" NPT conduit connection
¼" compression fitting (not included)
0.7 lbs (0.30 kg) |